Info
Below are general layout drawings and specifications of fire and smoke curtains in PDF format. If you require any of the drawings in CAD format, please contact us.
FB001 - 1DS - Firemaster testing for fire barrier shutter assemblies
FB002 - 1DS - Firemaster 2 & 4hr fire barrier impact resistance
FB004 - 1DS - Firemaster Variospeed Specifications
FB005 - 1DS - Firemaster uninsulated doorsets and shutter assemblies (Warrington Fire Research Testing)
FB006 - 1DS - Firemaster uninsulated doorsets and shutter assemblies (Loss Prevention Council Testing)
FB008 - 1DS - Firemaster fire barriers - project reference list
Firemaster side guide
Reverse mounted side guide
Firemaster headbox config
Controls
SER3 Standard (Wiring Diagram)
SER3 Standard & Detector (Wiring Diagram)
SER3 Transformer & Alarm (Wiring Diagram)
SER3 Transformer & Detector (Wiring Diagram)
SER3 Transformer & Fusible Link (Wiring Diagram)
SERV3_SB_01A - Servery General Arrangement
Servery Size Chart
SERV3_MC_12E - Servery Side Guides
SB001-1DS - Smokestop testing for automatic smoke barriers
SB002-1DS - Smokestop Variospeed Specifications - smoke barriers
SB007-1DS - Smokestop project reference list - smoke barriers
SB009-1DS - Smokestop active smoke barriers for life safety applications
SB012-1 - Smokestop multiple roller installation
Smoke barrier general detail
Controls
Coopers FireMaster provides a full fire rating for up to 4 hours at temperatures in excess of 1000°C. FireMaster fire curtains have been fully tested and certified to the following standards:
BS EN1634-1:2000: Fire resistance tests for door and shutter assemblies - Fire doors and shutters
BS EN1363-1:1999: Fire resistance tests - General requirements
BS EN1363-2:1999: Fire resistance tests - Alternative and additional procedures
EN12101-1:2003: Smoke and heat control systems - Specifications for smoke curtains
BS476-22:1987, Clause 8: Determination of the fire resistance of uninsulated doorsets and shutter assemblies
BS476-6:1989: Fire tests on building materials and structures - Methods of test for fire propagation for products
BS476-7:1997: Fire tests on building materials and structures - Methods of test to determine the classification of the surface spread of flame of products
BS476-20:1987: Fire tests on building materials and structures - Methods for determination of the fire resistance of elements of construction (general principles)