[image]Coopers logo

Information

Below are general layout drawings and specifications of fire and smoke curtains in PDF format. If you require any of the drawings in CAD format, please contact us.

Vertical and Horizontal Fire Curtains & Roller Fire Wall

[image]PDF icon FB001 - 1DS - Firemaster testing for fire barrier shutter assemblies
[image]PDF icon FB002 - 1DS - Firemaster 2 & 4hr fire barrier impact resistance
[image]PDF icon FB004 - 1DS - Firemaster Variospeed Specifications
[image]PDF icon FB005 - 1DS - Firemaster uninsulated doorsets and shutter assemblies (Warrington Fire Research Testing)
[image]PDF icon FB006 - 1DS - Firemaster uninsulated doorsets and shutter assemblies (Loss Prevention Council Testing)
[image]PDF icon FB008 - 1DS - Firemaster fire barriers - project reference list
[image]PDF icon Firemaster side guide
[image]PDF icon Reverse mounted side guide
[image]PDF icon Firemaster headbox config
[image]PDF icon Controls

Roller (Virtual) Fire Door & Servery Fire Curtain

[image]PDF icon SER3 Standard (Wiring Diagram)
[image]PDF icon SER3 Standard & Detector (Wiring Diagram)
[image]PDF icon SER3 Transformer & Alarm (Wiring Diagram)
[image]PDF icon SER3 Transformer & Detector (Wiring Diagram)
[image]PDF icon SER3 Transformer & Fusible Link (Wiring Diagram)
[image]PDF icon SERV3_SB_01A - Servery General Arrangement
[image]PDF icon Servery Size Chart
[image]PDF icon SERV3_MC_12E - Servery Side Guides

Vertical & Horizontal Smoke Curtains

[image]PDF icon SB001-1DS - Smokestop testing for automatic smoke barriers
[image]PDF icon SB002-1DS - Smokestop Variospeed Specifications - smoke barriers
[image]PDF icon SB007-1DS - Smokestop project reference list - smoke barriers
[image]PDF icon SB009-1DS - Smokestop active smoke barriers for life safety applications
[image]PDF icon SB012-1 - Smokestop multiple roller installation
[image]PDF icon Smoke barrier general detail
[image]PDF icon Controls

Fire Master Certification

Coopers FireMaster provides a full fire rating for up to 4 hours at temperatures in excess of 1000°C. FireMaster fire curtains have been fully tested and certified to the following standards:

BS EN1634-1:2000: Fire resistance tests for door and shutter assemblies - Fire doors and shutters
BS EN1363-1:1999: Fire resistance tests - General requirements
BS EN1363-2:1999: Fire resistance tests - Alternative and additional procedures
EN12101-1:2003: Smoke and heat control systems - Specifications for smoke curtains
BS476-22:1987, Clause 8: Determination of the fire resistance of uninsulated doorsets and shutter assemblies
BS476-6:1989: Fire tests on building materials and structures - Methods of test for fire propagation for products
BS476-7:1997: Fire tests on building materials and structures - Methods of test to determine the classification of the surface spread of flame of products
BS476-20:1987: Fire tests on building materials and structures - Methods for determination of the fire resistance of elements of construction (general principles)